Grbl_Esp32AlarmPosition isn't set yet: home first
The safety door was opened during homing.
Position isn't set yet: home first. Homing didn't finish. (Hamrun's reading)
What to do
- Close the door (or check the door switch input), then home again.
Name in the Grbl_Esp32 source:
HomingFailDoor. The meaning above is in Hamrun's words; Grbl_Esp32's own message text isn't copied here. sourceGot a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- GRBL 1.1 Alarm 7: The safety door was opened during homing.
- grblHAL Alarm 7: The safety door was opened during homing.
- FluidNC Alarm 7: The safety door was opened during homing.
- uCNC Alarm 7: The safety door was opened during homing.
- Grbl_Esp32 Alarm 6: Homing was interrupted by a reset before it finished.
- Grbl_Esp32 Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
- Grbl_Esp32 Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
Code name taken from the Grbl_Esp32 source on 2026-11-10; the meaning is in Hamrun's words and Grbl_Esp32's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.