Grbl_Esp32 Alarm 5
Grbl_Esp32AlarmPosition is kept
The probe moved its full distance and never touched the plate.
Position is kept. The probe move ended normally; it just didn't find contact. (Hamrun's reading)
What to do
- Check the plate is under the bit and the clip is on the bit (or the collet).
- Start the probe closer to the plate, or give it a longer probing distance.
- Touch the clip to the plate by hand and see whether the probe light changes. If it doesn't, check the probe wiring.
Name in the Grbl_Esp32 source:
ProbeFailContact. The meaning above is in Hamrun's words; Grbl_Esp32's own message text isn't copied here. sourceGot a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- GRBL 1.1 Alarm 5: The probe moved its full distance and never touched the plate.
- grblHAL Alarm 5: The probe moved its full distance and never touched the plate.
- FluidNC Alarm 5: The probe moved its full distance and never touched the plate.
- uCNC Alarm 5: The probe moved its full distance and never touched the plate.
Code name taken from the Grbl_Esp32 source on 2026-11-10; the meaning is in Hamrun's words and Grbl_Esp32's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.