GRBL 1.1 Error 11
GRBL 1.1ErrorPosition is kept
A line was longer than the controller can take, so it was skipped.
Position is kept. An error means the controller refused that one line or command, so nothing moved for it. (Hamrun's reading)
What to do
- Find the long line: usually a long comment, or numbers with too many decimal places.
- Set your CAM to 3 or 4 decimal places and keep comments short, or have your sender strip comments.
- GRBL 1.1 takes up to 80 characters per line (LINE_BUFFER_SIZE in its source).
Official GRBL 1.1 message: “Max characters per line exceeded. Received command line was not executed.” source
Got a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- grblHAL Error 11: A line was longer than the controller can take, so it was skipped.
- Grbl_Esp32 Error 11: A line was longer than the controller can take, so it was skipped.
- uCNC Error 11: A line was longer than the controller can take, so it was skipped.
Official text copied from the GRBL 1.1 source on 2026-11-01. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.